Skip to main content

Technical Specifications

Description​

SOL-LED+ is a professional photoperiod regulator designed for the automatic control of LED lighting systems powered by very low direct voltage.

The device integrates functions for:

  • progressive sunrise and sunset;
  • annual programs and personalized programs;
  • program Manual;
  • AstroGPS Timer;
  • night light;
  • night inspection;
  • energy saving;
  • management of auxiliary relays;
  • use at 1 room or 2 rooms.

General Data​

VoiceValue
ModelSOL-LED+
Technologydigital control via microcontroller
User Interfacedisplay with MENU, OK, arrows and INSP. buttons
Available languages ​​12 languages ​​

Power​

VoiceValue
Rated voltage12-24 V DC stabilized
Power typeSELV, very low safety voltage
Direct connection to the networknot expected
Installation environmentinternal, protected from water and condensation
Historical degree of protectionIP20
Operating temperature0 °C - +40 °C

Power must be supplied via a stabilized power supply, battery or accumulator compatible with the electrical limits of the product.


LED outputs​

The device manages two independent rooms/exits. Each room can be connected according to the type of bar used.

ExitUsageMaximum current
OUT-SG-1 / OUT-SG-2slashes SeasonGenerator PRO2,5 A for exit
OUT-1 / OUT-22 wire commercial LED bars 12-24V DC2,5 A for exit

Main light adjustment: PWM, 0 % - 100 %, limited by the Intensity' parameter.

Intensity' limit:

  • minimum 10 %;
  • maximum 100 %;
  • default value 80 %.

In Seasonal mode there are Min season and Max season; the minimum cannot exceed the maximum.


SeasonGenerator PRO releases​

ClampFunctionLimit
+positive LED bar power supply2,5 A max
Bblue LED channel / night light100 mA max
CPWM sunrise/day/sunset reference10 mA max
-common negative2,5 A max

2-wire outputs​

ClampFunctionLimit
+positive LED bar power supply2,5 A max
-common negative2,5 A max

Do not connect external LED drivers, LED power supplies, 230V lamps or inductive loads.


Auxiliary terminals​

ClampUsage
OPT-OUT - N.I.external night inspection control, via button between N.I. and GND
OPT-OUT - S1room 1 brightness sensor input, connected between S1 and GND
OPT-OUT - S2room 2 brightness sensor input, connected between S2 and GND
OPT-OUT - GNDcommon for N.I. button and brightness sensors
K-1relay coil power supply room 1, 100 mA max
K-2room 2 relay coil power supply, 100 mA max

The K-1 and K-2 outputs deliver the same voltage with which the device is powered. Use 12 V DC relay coils if SOL-LED+ is powered by 12 V DC, or 24 V DC relay coils if SOL-LED+ is powered by 24 V DC.

The K-1 and K-2 terminals must not be used to directly power the mains, lamps or final loads.


Main Parameters​

ParameterLimit / value
Intensity'Fixed / Seasonal
Mid season10 % - 100 %, not exceeding Max Season
Max season10 % - 100 %, default 80 %
Sunrise duration1 - 100 minutes
Sunset duration1 - 100 minutes
Night Light0 % (OFF) - 50 %
Relay PWM ON0 % - 100 %
Inspection time1 - 100 minutes
Inspection time1 - 100 minutes
Sensor limit0 % (OFF) - 100 %
Sensitivity0 % (OFF) - 20 %
Room use1 room / 2 rooms, default 2 rooms

Protections​

The fuse is internal to the device and cannot be replaced by the user. In the event of failure to turn on or if the fuse is suspected to have blown, do not open the product and contact assistance or an authorized dealer.


Memory and Clock​

Settings are stored in non-volatile memory and are retained even in the absence of power.

The control unit uses a single clock for both rooms. Stanza 2 shares the same time reference as stanza 1.


Content Subject to Change​

SeasonGenerator reserves the right to modify hardware, internal software, technical features and documentation without notice.