Programs
Introduction​
SOL-LED+ manages the photoperiod through programs selectable from the Use Program menu.
The control unit manages two rooms with separate programs and parameters. The active room may have a different program than the other room; the room change is managed by the dedicated button and by the room LED signaling. The clock is unique: in 1 room mode, room 2 is aligned with room 1.
If Room use is set to 1 room, the operational selection remains on room 1 and the second output copies the first. Room 2 programs become relevant again when you move Room use back to 2 rooms.
The names shown in this chapter are those shown on the display.
Actual menu path​
Route:
MENU -> Use Program
Screens displayed:
Use ProgramPrg:
With the UP and DOWN keys you scroll the list of programs. With ENTER you confirm the displayed program.
With MENU, from the Use Program screen, you go to the next screen of the main menu.
Program list​
The available programs are:
The names of the preloaded tables should not be interpreted as an exclusive restriction to the indicated species. They are practical names assigned to different light profiles: each table has its own seasonal trend, with minimum and maximum length of the day, growth and reduction of hours, sunrise and sunset times and ramp progression. For this reason, a table called, for example, Song thrush, REDWING, Fieldfare, Canaries or Crest Agi can also be used in different situations, when the light profile better corresponds to the objective of the farmer or user.
| Display Name | Usage |
|---|---|
Custom2 | personalized program with start/end date |
Personal | personalized program with daily variation + / - minutes |
Standard | general light profile, useful when there are multiple needs or multiple species in the same room |
Song thrush | preloaded light profile identified with this name |
REDWING | preloaded light profile identified with this name |
Skylark | preloaded light profile identified with this name |
Fieldfare | preloaded light profile identified with this name |
Breeding | preloaded light profile oriented towards breeding |
Finches | preloaded light profile identified with this name |
Canaries | preloaded light profile identified with this name |
Crest Agi | preloaded light profile identified with this name |
AstroGPS Timer | astronomical program from coordinates |
Manual | program with fixed times set by the user |
The programs listed can be selected directly from the Prg: menu.
Program Manual​
The Manual program uses fixed times set by the user. It does not apply daily increments and does not use an annual table.
When you confirm Prg: Manual, the display shows the sequence:
Sunrise beginSunset beginSunrise durationSunset duration
Use Manual when you want to keep the same on and off times every day.
Programs with preloaded table​
Programs with a preloaded table use sunrise and sunset values already stored in the device.
On the Season Generator website it is possible to see the behavior of the main tables and the times they represent day by day:
- Standard Table
- Bottaccio Table
- Sassello Table
- Lark Table
- Finches Table
- Canaries Table
- Agi and Crest Table
To advance or postpone the times in the table compared to those displayed, simply move the programmer date forwards or backwards. In this way the table also moves automatically and the user can adapt the period of greatest light to their needs.
For these programs the control unit calculates the daily times from the preloaded table and allows you to configure:
Sunrise durationSunset duration
Both parameters are expressed in minutes and have real limits:
- minimum:
1 - maximum:
100
Program Personal​
The Personal program does not use a default annual table. The user sets initial times and daily variations.
When you confirm Prg: Personal, the display shows the sequence:
Reset day/Count :Sunrise beginSunset begin+/-min Sunrise+/-min SunsetHow many days?Sunrise durationSunset duration
The detailed operation is described in chapter Tabella Personal.
Program Custom2​
The Custom2 program automatically calculates a progression between an initial photoperiod and a final photoperiod.
When you confirm Prg: Custom2, the display shows the sequence:
Start date phoSunrise todaySunset todayEnd date photoSunrise endSunset endSunrise durationSunset duration
The detailed operation is described in the Tabella Personal 2 chapter.
Program AstroGPS TimerThe AstroGPS Timer program calculates times using the Controller place, Simulated place, UTC: offset, and Twilight: setting.​
When you confirm Prg: AstroGPS Timer, the display shows the sequence:
Controller place/Lat:Controller place/Long:Controller place/UTC:Simulated place/Lat:Simulated place/Long:Twilight:
The detailed operation is described in chapter AstroGPS.
Common parameters after program selection​
For Manual, for the internal tables, for Personal and for Custom2, the control unit uses the parameters:
Sunrise durationSunset duration
These parameters regulate the duration of the on and off ramp.
For AstroGPS Timer, ramps are calculated based on astronomical events derived from Controller place, Simulated place, and Twilight:.