Panel and controls
This page describes the logic of use of the front controls.
Display​
The display shows:
- program status;
- configuration menu;
- editable values;
- any warning messages;
- references to language, time, date and light parameters.
Startup messages​
At power-on the display shows for about 4 seconds:
SEASONGENERATOR
SOL-7000
then, for about 4 more seconds, the firmware version:
SEASONGENERATOR
Vers. 1.9 B165
The main screen then appears.
Main screen​
The main screen is made up of several information pages. The pages change on their own every 5 seconds. Use UP and DOWN to scroll them manually: DOWN moves to the next page, UP goes back. After each key press the page stays visible for another 5 seconds.
Pages always present:
| Display | Meaning |
|---|---|
time and date, Prg= | current time, current date and program in use |
Sunrise / Sunset | today's sunrise and sunset times |
Total light time / Today | today's hours of light, from sunrise to sunset |
With the Manual program the main screen shows only the first two pages: time and date, Sunrise / Sunset.
Additional pages depending on the program:
| Program | Display | Meaning |
|---|---|---|
Personal | Days counter / n OF n | day reached in the progression, out of the How many days? value set |
Personal | Total light time / On day | hours of light expected on the last day of the progression |
Custom2 | Total light hr / end prog | hours of light expected on the end date |
Custom2 | Day | current day / total days of the program |
AstroGPS | Twil Beg / Twil End | start and end of twilight; OFF if twilight is disabled |
With AstroGPS, Sunrise and Sunset indicate sunrise and sunset at the simulated location.
With Use mode set to Only lamp the following also appear:
| Display | Meaning |
|---|---|
Light min | maximum lamp intensity in the shortest light period |
Light today | maximum lamp intensity for today |
Light max | maximum lamp intensity in the longest light period |
With the Fixed limit the three values are the same. See Lamp limit.
With Energy saving set to With sensor the following also appear:
| Display | Meaning |
|---|---|
Brightness | light currently read by the sensor |
Switch off | threshold set in Sensor limit |
Sensitivity | sensitivity set |
See Energy saving.
If the lamp map must be redone, the first page stays still and the second line alternates Redo lamp map and the program. See Lamp profiles.
Keys​
| Key | Function |
|---|---|
MENU | enters the menu and moves to the next item; in date screens it increases the year |
OK | confirms and saves the value |
UP | increases the value or changes the choice; in time screens it increases the minutes |
DOWN | decreases the value or changes the choice; in date screens it increases the day |
LEFT | in time screens it increases the hours |
RIGHT | in date screens it increases the month; in AstroGPS it moves the cursor |
INSP. | manages the night inspection |
Exact wordings may vary depending on panel graphics.
Holding a key down repeats its function: the first repeat comes after 0.8 seconds, then one every 0.2 seconds. This is useful for scrolling quickly through long values, such as minutes or percentages.
Backlight​
The display backlight switches off 5 minutes after the last key press.
The first key pressed while the display is off switches the backlight back on and also performs its function. To switch the display back on without changing anything, press UP or DOWN from the main screen.
Navigation​
Rule of thumb:
- press
MENUto enter configuration; - press
MENUagain to reach the item; - use the arrows to modify;
- confirm with
OK; - wait to return to the main screen or exit the menu.
From the main screen, pressing MENU repeatedly shows the items in this order:
Use ProgramEnergy/SavingNight LightInspection timeModify/Date / TimeCurr.RMS/Device tmp(measurements)Use modeLamp limit, only withOnly lampDimming typeMains freq.Select languageFactory reset
After Factory reset, MENU returns to the main screen.
If no key is pressed for 30 seconds, the display returns to the main screen on its own.
Measurements​
After Modify / Date / Time, pressing MENU shows the measurement screen:
| Display | Meaning |
|---|---|
Curr.RMS | current drawn by the outputs, in amperes |
Device tmp | internal temperature of the device, in degrees Celsius |
The values update in real time and cannot be changed.
OKreturns to the main screen;MENUmoves toUse mode.
This screen is useful during commissioning, to check the lamp current draw and the controller temperature.
Language​
The SOL-7000 menu is available in 12 languages: Italian, English, French, German, Spanish, Portuguese, Dutch, Hebrew (transliterated), Polish, Romanian, Turkish and Greek (transliterated).
Changing the menu language​
- from the main screen, press
MENUrepeatedly to scroll through the menu items; - after
Dimming typeandMains freq.theSelect languagescreen appears; - use
UPandDOWNto scroll through the languages: the display switches language immediately and shows the name of the selected language; - press
OKto save: the controller returns to the main screen and uses the new language from then on.
Pressing MENU instead of OK moves to the next item without saving the language permanently.
The language screen is always the item that follows the 50 Hz / 60 Hz choice. Press MENU until the display shows 50 Hz or 60 Hz, press MENU once more, then choose the language with UP / DOWN and confirm with OK.
When an item on the display is abbreviated, the operational meaning is indicated in the manual instead of just the abbreviation.
Factory reset​
Factory reset is the last menu item. It restores all settings to their factory values.
Path:
MENU -> ... -> Select language -> MENU -> Factory reset
Procedure:
- the display shows
Factory resetandConfirm: NO; - use
UPorDOWNto chooseConfirm: YES; - press
OK; - the display shows
Reset doneandPress OK; - press
OKto return to the main screen.
With Confirm: NO and OK, or by pressing MENU, you exit without changing anything.
After the reset:
| Setting | Value |
|---|---|
| time and date | the clock restarts from 00:00 on 01/01/25 |
| language | Italian |
| program | Personal, with times at 00:00 |
Sunrise duration / Sunset duration | 20 min |
Inspection time (entry and exit) | 1 min |
Night Light | OFF |
Energy saving | Disabled |
Use mode | Lamp+Neon |
Lamp limit | Fixed, 100 % |
Dimming type | LXM-11W-977813 |
Mains freq. | 50 Hz |
AstroGPS | controller location and simulated location Canary Islands, UTC: +00:00, twilight Enabled |
The lamp map created with Lamp map is not erased: to use it again, select Custom in Dimming type.
After a reset always set again:
- time and date;
- program and its times;
Mains freq., if the installation runs at 60 Hz;- all other functions used in the installation.
Output status​
SOL-7000 can control lamp, neon and dimming according to the product configuration.
If the device detects an abnormal condition, it switches off the outputs and displays a warning message. While these messages are shown the keys are not active.
| Display | Cause | Recovery |
|---|---|---|
Temp exceeded! / Wait cooling | internal temperature of 70 °C or more | the outputs switch back on by themselves when the temperature drops to 60 °C |
Current high! / System reset | current above the limit (factory 2.20 A) for 10 seconds, or above 4 A even for an instant | the outputs stay off until the controller is switched off and on again |
In these cases, check the lamp, connections and environmental conditions before restarting. See also Troubleshooting.