Technical Specifications
General data​
| Voice | Value |
|---|---|
| Model | SOL-LED |
| Brand | Season Generator |
| Product Type | professional photoperiod controller |
| Startup display | Season Generator / SoL-Led |
| Interface | LCD display, MENU, OK keys, arrows, INSP. |
| Languages ​​ | 12 |
Power​
| Voice | Value |
|---|---|
| Rated voltage | 12-24 V DC stabilized |
| Direct connection to network | not expected |
| Installation type | internal |
| Historical degree of protection | IP20 |
| Historical operating temperature | 0 C - +40 C |
LED outputs​
| Exit | Usage | Maximum current |
|---|---|---|
OUT-SG-1 / OUT-SG-2 | slashes SeasonGenerator PRO | 2,5 A for exit |
OUT-1 / OUT-2 | 2 wire commercial LED bars 12-24 V DC | 2,5 A for exit |
Main light adjustment: PWM, limited by the Intensity parameter.
Parameter limits​
| Parameter | Values ​​ | Default |
|---|---|---|
Sunrise duration | 1 - 100 min | 10 min |
Sunset duration | 1 - 100 min | 10 min |
+/-min Sunrise | -100 - +100 min/day | 0 |
+/-min Sunset | -100 - +100 min/day | 0 |
How many days? | 0 - 365 days | 0 |
Max. Brightness | 10 % - 100 % | 80 % |
Night Light | OFF - 50 % | OFF |
Inspection time | 1 - 100 min | 1 min |
Inspection time | 1 - 100 min | 1 min |
Intensity | Fixed / Seasonal | Fixed |
Mid season | 10 % - 100 % | 10 % |
Max season | 10 % - 100 % | 80 % |
Language | 12 languages ​​ | Italian if invalid |
Programs​
The Prg: menu manages:
Personal;Custom2;AstroGPS Timer;Manual;Standard;Song thrush;REDWING;Skylark;Fieldfare;Breeding;Finches;Canaries;Crest Agi.
Memory and clock​
The settings are saved in EEPROM.
The device uses an internal clock shared by the two rooms.
Current protection​
The device monitors the current of the outputs and limits the ramp if an exceeding of the internal limit is detected.
The internal protection limits must not be used as authorization to exceed the load limits indicated in the manual.