Skip to main content

Technical Specifications

General data​

VoiceValue
ModelSOL-LED
BrandSeason Generator
Product Typeprofessional photoperiod controller
Startup displaySeason Generator / SoL-Led
InterfaceLCD display, MENU, OK keys, arrows, INSP.
Languages ​​12

Power​

VoiceValue
Rated voltage12-24 V DC stabilized
Direct connection to networknot expected
Installation typeinternal
Historical degree of protectionIP20
Historical operating temperature0 C - +40 C

LED outputs​

ExitUsageMaximum current
OUT-SG-1 / OUT-SG-2slashes SeasonGenerator PRO2,5 A for exit
OUT-1 / OUT-22 wire commercial LED bars 12-24 V DC2,5 A for exit

Main light adjustment: PWM, limited by the Intensity parameter.

Parameter limits​

ParameterValues ​​Default
Sunrise duration1 - 100 min10 min
Sunset duration1 - 100 min10 min
+/-min Sunrise-100 - +100 min/day0
+/-min Sunset-100 - +100 min/day0
How many days?0 - 365 days0
Max. Brightness10 % - 100 %80 %
Night LightOFF - 50 %OFF
Inspection time1 - 100 min1 min
Inspection time1 - 100 min1 min
IntensityFixed / SeasonalFixed
Mid season10 % - 100 %10 %
Max season10 % - 100 %80 %
Language12 languages ​​Italian if invalid

Programs​

The Prg: menu manages:

  • Personal;
  • Custom2;
  • AstroGPS Timer;
  • Manual;
  • Standard;
  • Song thrush;
  • REDWING;
  • Skylark;
  • Fieldfare;
  • Breeding;
  • Finches;
  • Canaries;
  • Crest Agi.

Memory and clock​

The settings are saved in EEPROM.

The device uses an internal clock shared by the two rooms.

Current protection​

The device monitors the current of the outputs and limits the ramp if an exceeding of the internal limit is detected.

The internal protection limits must not be used as authorization to exceed the load limits indicated in the manual.