Energy Saving

What is it for​

Energy saving allows you to reduce the consumption of the system by exploiting, when available, the natural light coming from outside.

If during some hours of the day the light entering through the windows already illuminates the room correctly, it is not necessary to keep the LED bars or system lamps switched on. The control unit can then temporarily turn off the artificial lighting and then automatically return to the daily program.

On the SOL-LED the function works on a timed basis: the user sets a period of the day in which he knows that the room normally receives sufficient natural light.

These modes are managed:

Display ModeUsage
Disabledno energy savings
No sensorswitching off in the set time slot

Route:

MENU -> Energy Saving -> OK

Screenshot:

Energy saving

Use up arrow and down arrow to change mode and OK to confirm.

Disabled mode​

Select Disabled when you want to always follow the light program without saving interventions.

Press OK to save and return to the main page.

Sensorless mode​

The No sensor mode turns off the light in a time slot set by the user.

This mode does not require sensors. It is indicated when the natural lighting of the room is quite predictable: for example, if the program foresees sunrise at 06:30 and sunset at 21:00, but between 11:00 and 14:00 the room receives sufficient light from the windows, that period can be set as a saving period.

Menu sequence:

  1. Turn off lights / From hours
  2. Turn off lights / Up to hours
  3. Turn-oFF Turn-ON / Gradual:

Shutdown time​

To the From hours screen:

| Field | | button | --- | --- | | Now | left arrow | | Minutes | up arrow | | Confirm | OK |

Restart time​

At the Up to hours screen use the same keys.

Gradual Off-On​

OptionEffect
YESentry and exit from the band with gradual progress
NOimmediate switching off and on again

Press OK to save.

Practical note​

Set the savings band only when you are sure that natural light is sufficient for the room during those hours. Once the interval is over, the device automatically resumes normal program management.