Troubleshooting
The device does not turn on​
Check:
- power supply turned on;
- voltage
12-24 V DC; - correct polarity;
- clamps tightened;
- absence of short circuits.
If the device remains off, disconnect the power and contact service or dealer. Do not open the device.
The light does not turn on​
Check:
- selected room;
- active program;
- time and date;
- value
Max brightness; - correct connection of the LED bar;
- current absorbed by the load;
- possible active energy saving.
The light stays on during the night​
Check:
INSP.button and inspection LED;- value
Night Light; - sunrise/sunset times;
- selected program.
If the inspection LED is on or flashing, press INSP. until it turns off.
The light turns off during the day​
Possible causes:
- energy saving
No sensoractive in the set time slot; - overcurrent or load beyond limit;
- incorrect wiring.
The two rooms do not follow the same program​
SOL-LED manages two separate parameter sets.
Press right arrow to select the correct room and check:
- program;
- dawn duration;
- sunset duration;
- maximum brightness;
- night light;
- energy saving.
The Personal program does not restart from day one​
When creating a new Personal program, select YES over Reset day.
If you select NO, the device keeps the previous day counter.
Energy saving does not turn off the light​
Check:
No sensormode;- time
From hours; Up to hourstime;Gradual Off-Onsetting;- device time and date.
The menu automatically returns to the main page​
It's normal. After about 30 seconds without keys the device returns to the main page.