Skip to main content

Troubleshooting

The device does not turn on​

Check:

  • power supply turned on;
  • voltage 12-24 V DC;
  • correct polarity;
  • clamps tightened;
  • absence of short circuits.

If the device remains off, disconnect the power and contact service or dealer. Do not open the device.

The light does not turn on​

Check:

  • selected room;
  • active program;
  • time and date;
  • value Max brightness;
  • correct connection of the LED bar;
  • current absorbed by the load;
  • possible active energy saving.

The light stays on during the night​

Check:

  • INSP. button and inspection LED;
  • value Night Light;
  • sunrise/sunset times;
  • selected program.

If the inspection LED is on or flashing, press INSP. until it turns off.

The light turns off during the day​

Possible causes:

  • energy saving No sensor active in the set time slot;
  • overcurrent or load beyond limit;
  • incorrect wiring.

The two rooms do not follow the same program​

SOL-LED manages two separate parameter sets.

Press right arrow to select the correct room and check:

  • program;
  • dawn duration;
  • sunset duration;
  • maximum brightness;
  • night light;
  • energy saving.

The Personal program does not restart from day one​

When creating a new Personal program, select YES over Reset day.

If you select NO, the device keeps the previous day counter.

Energy saving does not turn off the light​

Check:

  • No sensor mode;
  • time From hours;
  • Up to hours time;
  • Gradual Off-On setting;
  • device time and date.

The menu automatically returns to the main page​

It's normal. After about 30 seconds without keys the device returns to the main page.