Night inspection
What is it for​
The INSP. function allows you to enter the room when the light is off and make a short visit while disturbing the birds as little as possible.
By pressing the button, the device starts a quick little dawn: the light gradually rises instead of turning on suddenly.
When the light is bright enough to see into the room, press INSP. again. In this way the level is blocked at the point reached, without causing the light to rise further.
At the end of the visit, press INSP. again to exit. The light must go off: only then will the device return to the main program. If the inspection remains active, the light can remain on and the normal day-night cycle is excluded.
Using the INSP button.​
The INSP. button works in cycles:
| Pressure | Status |
|---|---|
| first press | inspection active, light up and warning light on |
| second press | light stuck at the level reached, light flashing |
| final pressure | exited inspection, light off |
When the inspection LED is off, the device returns to following the automatic programs.
Before leaving the room, check that the inspection LED is off. If it stays on or flashes, the inspection may keep the light out of normal programming.
Inspection entry duration​
Route:
MENU -> Inspection Input
This parameter regulates the duration of the inspection start-up ramp.
Values:
- minimum
1minute; - maximum
100minutes; - default
1minute.
Inspection exit duration​
After Inspection time the display shows:
Inspection time
This parameter adjusts the duration of the inspection shutdown ramp.
Values:
- minimum
1minute; - maximum
100minutes; - default
1minute.
Selection of inspection rooms​
After the entry and exit durations, the display shows:
Night insp.sel
Options:
| Display option | Effect |
|---|---|
room 1 | inspection applied to room 1 |
room 2 | inspection applied to room 2 |
room 1+2 | inspection applied to both |
Use up arrow and down arrow to choose and OK to confirm.
Remote accessory​
The inspection button can be remoted with an optional Season Generator kit, or with a clean button contact when required by the electrical diagram supplied.
The remote button can be installed, for example, near the door of the room or inside an electrical system. Pressing it gives the same effect as the INSP. button on the programmer.
The remote contact must not carry external voltage to the device.